8. Enter the cage platform. Ensure that the cage gate is closed and engaged prop-
erly. A proximity switch in the gate will prevent operation of the lift if the gate is
not properly closed.
9. The lift is now ready for operation. While depressing the
ENABLE pushbutton, se-
lect the
UP or DOWN pushbutton on the transmitter. The platform will raise or
lower respectively. The
EMERGENCY STOP pushbutton deactivates the control
circuit.
3-3 EMERGENCY LOWERING PROCEDURE
The Odyssey 34 lift is equipped with a manual lowering valve in case of emergency situa-
tions to lower the platform. The emergency lowering valve is located on the hydraulic
pump. The valve may be accessed through the opening on the side of the machine. To
lower the platform, turn the red knob on the valve counterclockwise. Refer to Figure 3-6.
EMERGENCY
LOWERING
VALVE
Figure 3-6. Emergency Lowering Valve