A SERVICE OF

logo

30
LIMIT ADJUSTMENT PROCEDURE
Ÿ WARNING: TURN OFF MAIN POWER BEFORE MAKING ANY
ADJUSTMENTS!
1. After the gate is mechanically installed, disengage operator drive
with the manual disconnect lever. Move the gate to a midway
position.
NOTE:
When moving the gate with the operator disengaged, the limit
nuts on the limit assembly inside the operator can be driven passed
their normal position. Reset the limit nuts as necessary, by
depressing the pressure plate and rotating the limit nuts until they are
both positioned near the center of the limit shaft.
Limit Assembly
Limit Assembly
Press Down
On Pressure
Plate
Rotate Limit
Nuts To Center
1"
1"
Open Limit
Switch
Pressure
Plate
Limit nut
Close Limit
Switch