A SERVICE OF

logo

41
7. Mount the loop detector in the operator and connect the wire loop.
8. Connect loop detector to the control board as shown in the following
diagrams.
V
OR
R
P
Not Used
BL
BK
WH
Y
GR
BR
GY
TO
DRIVEWAY
LOOP
REVERSING LOOP CONNECTION
NOTE: TWIST LEADS APPOX.
6 TURNS PER FOOT.
COM
COM
COM
24V
AC
24V
AC
ALT
RDO
OPN
CRO
FRE
OPN
CLO
STO
COM
COM
COM
OPN
PHO
CLO
PHO
SHW
REV
OPN
EDG
CLOSE
PHOTO
OPEN
PHOTO
LD17
LD13
FORCE
ADJUSTMENT
TB1
TB2
V
OR
R
P
Not Used
BL
BK
WH
Y
GR
BR
GY
TO DRIVEWAY
LOOP
NOTE: TWIST LEADS APPOX.
6 TURNS PER FOOT.
COM
COM
COM
24V
AC
24V
AC
ALT
RDO
OPN
CRO
FRE
OPN
CLO
STO
COM
STOP
PUSH
CLOSE
PHOTO
OPEN
PHOTO
LD16
LD17
LD13
FORCE
ADJUSTMENT
TB1
U4
EXIT LOOP CONNECTION