2. With the gate at mid travel, depress the pressure plate and set
the grooved limit nuts approximately 1 inch from the limit
switches on each side.
3. Check that Dipswitch #2 is in the correct position for left or right
hand operation as determined by the location of the gate opener,
when viewed from inside the fenced area.
12
3
4
5
ON
OFF
12
3
4
5
ON
OFF
Place Dipswitch #2
In "ON" Position For Left
Hand Operation And
"OFF" Position For Right
Hand Operation.
Left Hand
Operation
Right Hand
Operation
COM
COM
COM
24V
AC
24V
AC
ALT
RDO
OPN
CRO
FRE
OPN
CLO
STO
COM
COM
COM
OPN
PHO
CLO
PHO
SHW
REV
OPN
EDG
CLO
EDG
MST
OPN
MST
CLO
COM
COM
COM
OPEN
PUSH
FREE
EXT
ALT
RADIO
OPN/
CLO
RADIO
OPEN
CLOSE
PUSH
STOP
PUSH
CLOSE
PHOTO
OPEN
PHOTO
LD18
LD10
LD11
LD12
LD15
LD14
LD16
LD17
LD13
OPEN
CLOSE
STOP
OPEN CLOSE
FORCE
ADJUSTMENT
AUTO
RECLOSE
TIMER
OFF MAX
MID
LIMIT
REV
LOOP
OPN
EDGE
CLO
EDGE
RH OPN
LH CLO
LIMIT
RH CLO
LH OPN
LIMIT
MOTOR
OPEN
MOTOR
CLOSE
SHADOW
LOOP
LD19
LD2
LD3
LD4
LD5
LD6
LD8
LD9
LD7
12345
POWER
LD1
P3
P4
TB1
TB2
U1
U2
U4
4. Turn on power, and re-engage operator with manual disconnect
lever.
NOTE:
Operator will not run if manual disconnect lever is in the
disengaged position.