3M 2550 Cable Box User Manual


 
10 78-9000-0192-2 Rev C
F. Transmitter 2573Keypad and Connector Definitions
off
+
-
o
Trace
on
on
Output Level
Dynatel
TM
2573
T-1 T-2 T-3 T-4 T-5 T-6 T-7
[T-1] off: Turns unit off and performs battery test.
[T-2] on: Ohm-meter/Fault Locate/Tone: Turns the unit on and cycles through the
following commands when pressed repeatedly.
Ohm-meter: Measures the continuity of the trace conductor/pipe and its far-end
ground. It is also used to measure the fault resistance to earth.
Fault Locate: In this mode, the transmitter sends two alternating locating frequencies
(577 Hz and 33 kHz) as well as fault signals 10 and 20 Hz.
Tone: In the tone mode, the transmitter generates 577 Hz and 200 kHz signals.
[T-3] on: Trace (frequency): Turns the unit on and places the unit in Trace mode.
Select Frequency: Press Trace [T-3] repeatedly to cycle through the transmitter's
active frequencies (577 Hz, 1 kHz, 8 kHz, 33 kHz, 82 kHz and 200 kHz). The
selected frequency will be displayed [T-4]. ‘ALL’ indicates that the following active
frequencies are transmitting simultaneously: 577 Hz, 8 kHz, 33 kHz and 200 kHz.
[T-4] Digital Display:
Indicator Flags: These flags coincide with the operational mode of the transmitter.
(From top left to bottom right) Fault Locate mode [T-2], Tone mode [T-2], Trace
mode [T-3], Ohm-meter [T-2], Voltage (at start up the transmitter checks for foreign
voltage), and the Output Level [T-5] (no flag = normal output; flag = high output;
flashing flag = maximum output).
Digital Display: Indicates frequency, relative current, resistance, battery level and
voltage (if present on target).
[T-5] Output Level: Cycles output power level; normal, high and maximum.
Normal=No Flag; High=Flag; Maximum=Flashing Flag (indicated in Digital Display [T-4])
NOTE: An external 12-volt power source is required to obtain Maximum Output level.
NOTE: 12-watt output level varies by frequency. Output is limited to 10 watts at
33 kHz and 1 watt at 82 kHz and 200 kHz using the direct connection method.
[T-6] Output Jack: Port for direct connect cables or Dyna-coupler cable.
[T-7] External Jack: Port to connect cigarette lighter adapter cable, or rechargeable
battery (2200RB). Input voltage level: 9-18 VDC. (Only on 12-watt transmitters.)