Eiki LC-XS25 CRT Television User Manual


 
55
Setting Setting
This function provides the following alternatives in the
cooling fans' operation after turning off the projector. (p.19)
L1
. . . . . . normal operation
L2
. . . . . . s
lower and lower-sound than the normal
operation (L1), but it takes longer to cool the
projector down.
Fan
This function is used to reset the lamp replacement
counter. When replacing the projection lamp, reset the
lamp replacement counter by using this function. See
page 62 for operation.
Lamp counter
Note:
Do not reset the Lamp replacement counter without
implementation of lamp replacement. Be sure to
reset the Lamp replacement counter only after
replacing the lamp.
Warning log
This function records anomalous operations while the
projector is in operation and use it when diagnosing faults.
Up to 10 warning logs are displayed with the latest warning
message at the top of the list, followed by previous warning
messages in chronological order.
Note:
When the Factory default function is executed, all the
warning log records will be deleted.
This icon appears on the screen when the
end of lamp life is reached.
Lamp replacement icon
Note:
This icon also appears at turning on and
selecting input source.