Emerson 6420FE CRT Television User Manual


 
5-2 L2401EA
2. Initial Setting
General
1. Enter the Service mode. (See page 5-1)
2. Press "VOL p" button on the service remote control
unit. Display changes "C/D," "7F," "LANGUAGE,"
"ACCESS CODE," "SOUND TYPE," "VIDEO
TONE," "FM MODE," "V-OUT," "VIDEO," "AV
MEMO," "STABLE SOUND," "FILTER," "1000,"
"YUV MEMORY," "NO SIG BRT," "A-MUTE POL,"
and "V-MENU" cyclically when "VOL p" button is
pressed.
3. To set the following each data value, press "CH o
/ p" buttons on the service remote control unit.
7F --- Set to "FF."
LANGUAGE --- Set to "SPA/FRA."
ACCESS CODE --- Set to "OFF."
SOUND TYPE --- Set to "MTS."
VIDEO TONE --- Set to "ON."
FM-MODE --- Set to "OFF."
V-OUT --- Set to "OFF."
VIDEO --- Set to "V1/V2."
AV MEMO --- Set to "OFF."
STABLE SOUND --- Set to "OFF."
FILTER --- Set to "OFF."
Adjusting the monitoring time
--- Set to "1000."
YUV MEMORY --- Set to "OFF."
NO SIG BRT --- Set to "0."
A-MUTE POL --- Set to "H."
V-MENU --- Set to "OFF."
3. Setting for BRIGHT, CONTRAST,
COLOR, TINT, and SHARPNESS
data Values
General
1. Enter the Service mode. (See page 5-1)
2. Press "MENU" button on the service remote control
unit. Display changes "BRT," "CNT," "CLR," "S-
CLR," "TNT," "V-TNT," "S-TNT," "SHARP," and
"S-SRP," cyclically when "MENU" button is
pressed.
CNT
1. Press "MENU" button on the service remote control
unit. Then select "CONTRAST" (CNT) display.
2. Press "CH o/p" buttons on the service remote
control unit so that the value of "CONTRAS" (CNT)
becomes 84.
CLR
1. Press "MENU" button on the service remote con-
trol unit. Then select "COLOR" (CLR) display.
2. Press "CH o/p" buttons on the service remote
control unit so that the value of "COLOR" (CLR)
becomes 58.
S-CLR
1. Press "MENU" button on the service remote con-
trol unit. Then select "S-COLOR" (S-CLR) display.
2. Press "CH o/p" buttons on the service remote
control unit so that the value of "S-COLOR" (S-
CLR) becomes 58.
TNT
1. Press "MENU" button on the service remote con-
trol unit. Then select "TINT" (TNT) display.
2. Press "CH o/p" buttons on the service remote
control unit so that the value of "TINT" (TNT) be-
comes 60.
V-TNT
1. Press "MENU" button on the service remote con-
trol unit. Then select "V-TINT" (V-TNT) display.
2. Press "CH o/p" buttons on the service remote
control unit so that the value of "V-TINT" (V-TNT)
becomes 60.
S-TNT
1. Press "MENU" button on the service remote con-
trol unit. Then select "S-TINT" (S-TNT) display.
2. Press "CH o/p" buttons on the service remote
control unit so that the value of "S-TINT" (S-TNT)
becomes 60.
SHARP
1. Press "MENU" button on the service remote con-
trol unit. Then select "SHARPNESS" (SHARP) dis-
play.
2. Press "CH o/p" buttons on the service remote
control unit and select "43."
S-SRP
1. Press "MENU" button on the service remote con-
trol unit. Then select "S-SHARPNESS" (S-SRP)
display.
2. Press "CH o/p" buttons on the service remote
control unit and select "43."
Note: BRIGHT data value does not need to be adjust-
ed at this moment.