Fostex D-108 DVR User Manual


 
121
D-108 Owner’s Manual (Changing the initial setting <SETUP mode>)
1. Press the DISP SEL key and choose the flashing SETUP
mode on the display. Then, press the EXECUTE/YES key.
The SETUP display will stop flashing.
2. With the JOG dial, choose “Device ID?”.
The “?” display will start flashing.
The display will also show the current setting. In the case of
the initial setting, it will show “00”.
3. Press the EXECUTE/YES key.
The current setting will start flashing “**” which indicates it
is ready to change setting.
4. With the JOG dial, enter a required ID number.
The available setting is from 00 ~ 99.
5. Press the EXECUTE/YES key once again.
The setting will be registered and the display will go back to
step 2.
* Press either the STOP button or EXIT/NO key to return
from the second step to the first or to quit SETUP mode.
The menu will go backwards each time you press either
key so that you can correct the setting, choose some other
SETUP mode or eventually return to the normal time base
display.
Sampling Frequency Setting ("Sample Rate ? ")
The D-108 can handle two types of sampling frequency, either 44.1k or 48 kHz.
This mode allows you to set either sampling frequency. The display will show the registered sampling frequency.
* Initial setting : 44.1kHz
* Available setting : 44.1kHz, 48kHz
* This setting is applicable song by song.
* This setting can be saved or loaded as a part of the song data.
* The setting is memorized even when the power is off.
44.1kHz
SETUP
8
7
6
5
4
32
1
42
OL
0
30
24
18
12
9
6
3
44.1kHz
SETUP
8
7
6
5
4
32
1
42
OL
0
30
24
18
12
9
6
3
1. Press the DISP SEL key and choose the flashing SETUP
mode on the display. Then, press the EXECUTE/YES key.
The SETUP display stops flashing.
2. With the JOG dial, choose “Sample Rate?”.
The “?” display will start flashing. The display will also show
the current setting. In the case of the initial setting, it will
show “44.1”.
3. Press the EXECUTE/YES key.
The current setting will start flashing which indicates it is
ready to change setting.
4. With the JOG dial, choose either “44.1” or “48” .
5. Press the EXECUTE/YES key to process.
The setting will be registered and the display will go back to
step 2. Or If you are not changing the sampling frequency,
press the EXIT/NO key or STOP button to quit the SETUP
mode.
44.1kHz
SETUP
87654321
42
OL
0
30
24
18
12
9
6
3
44.1kHz
SETUP
87654321
42
OL
0
30
24
18
12
9
6
3
6. Press the STOP button or EXIT/NO key to come out of this
mode.
The display will go back to the normal time base display.
* Press either the STOP button or EXIT/NO key to return
from the second step menu to the first or to quit SETUP
mode. The menu will go backwards each time you press
either key so that you can correct the setting, choose
some other SETUP mode or eventually return to the nor-
mal time base display.
<Notes>
* The total recording length will be shorter with 48kHz
sampling than 44.1kHz sampling due to the hard disk space
usage. The REMAIN time display will be shorter with 48kHz
than 44.1kHz as well.
* Except for certain special use, avoid changing the
sampling frequency within a program .
It is possible to set the D-108 to a different sampling
frequency than its original song recording frequency.
However, the play back speed will become different from
the original and the registered memory key data will be
come a different value.