Ingersoll-Rand ETA2 TV Converter Box User Manual


 
59
Code Message Explanation
123 AZ DISCR An auto-zero calibration on the transducer has
detected an excessive discrepancy between the
Tracking and Peak inputs.
124 Tx FAULT Adc saturation due to transducer fault, no
transducer fitted or over torque.
200 INCOR-TX The correct transducer is not connected.
300 IN ROUND This characteristic has already been included in
the round.
301 CHARACTS A minimum of two characteristics must be defined
before entering Edit Round.
306 RS232 Invalid RS232 data on the serial input.
400 INVALID Incorrect time or date format.
600 ONLY 1 Only one round programmed so not possible to
generate master round.
601 NO RND No rounds programmed so not possible to gener-
ate master round.
602 IN M RND This round has already been entered into the
master round. It is not possible to enter a round
twice.
701 RND COMP The round is complete, no skipping is allowed.
702 ALL SKIP All other characteristics have already been
skipped.
800 MEMORY Message on power up if memory error found.
(See note below)
801 MENU ERR Invalid menu entered due to fault.
802 PROM CKS The EPROM has an error.
7529_eng.fm Page 59 Wednesday, November 12, 2003 8:57 AM