HMP Linux 1.2 Release Update, Rev 05 — September 2006 16
IPY00009204 33894 6 CSP/Voice During heavy load, while running CSP and voice together,
the HMP system may miss an event and have a channel
stay busy.
IPY00009082 33762 6 Global Call Segmentation fault in gc_Start() when more than 1024
files have been opened prior to calling gc_Start(). If 1024
files are opened after gc_Start() and after opening the
devices, no calls can be established.
IPY00009801 33644 6 HMP The interface does not indicate if it is necessary to reboot
after activating a license and uninstalling the software. If
there is a reboot message in the software script, it scrolls
too quickly for users to see.
IPY00009304 33638 6 HMP Difficult to see the "success" messages on the screen
because several error messages run into the "success'
message.
IPY00011176 33609 6 Install HMP Linux 1.2 software will not install correctly on a
system that does not have compat-libstdc++-7.3-
2.96.123.i386.rpm installed. The following error message
is displayed when the HMP configuration script is run:
fcdgen: error while loading shared
libraries: libstdc++-libc6.2-2.so.3: cannot
open shared object file: No such file or
directory.
IPY00011219 33449 6 Install If you try to use the install script a second time to install a
package that has already been installed, disk space check
will fail and the install script will terminate and exit. The
disk space check failure does not necessarily mean the
system is low on disk space.
IPY00011186 33401 6 Global Call Applications running H.323 under Global Call with the
default list of coders (don’t care) will see error messages
on the console.
IPY00011189 33395 6 License
Manager
The LicenseManager program includes the -l option, which
reads and executes commands from the
LicenseManager.ini file. The LicenseManager expects this
file to reside in /usr/dialogic/ini, but the ini subdirectory
does not currently exist in HMP LInux 1.2.
IPY00011191 33393 6 CSP Segmentation Fault occurs in the IP Media Server demo if
the CSP option is chosen and a non-CSP licensed is
installed.
IPY00011217 33386 6 Global Call Applications running H.323 under Global Call may get
GCEV_DISCONNECTED for an outbound call with the
error message:
IPEC_Q931TransportError(0xE75)
This error is caused by socket errors.
IPY00011248 33380 6 CSP The ec_stream() and ec_reciottdata() functions do not
return errors back to the application when an unsupported
recorded format is used.
Table 1. Issues Resolved in HMP 1.2 (Continued)
Defect
Number
PTR
Number
SU
No.
Product or
Component
Description