JVC RM-P210 Universal Remote User Manual


 
30
TROUBLESHOOTING
GENERAL
Colors in the monitor screen
are abnormal. (During
genlocking)
Is the SC phase adjusted properly?
P. 13
Synchronization is not
possible.
Are the BB or VBS signals applied to the GENLOCK INPUT
connectors?
Is the VCR playback signal supplied directly without passing
through a TBC?
P. 13
The LCD display keeps on
displaying "NOW INITIALIZING
JUST A MOMENT" or "PLEASE
CHECK THE CAMERA".
Are cables connected properly?
Are the power switches of the RM-P210 and camera set to ON?
Is the MODE (RM/VTR) switch on the camera adapter set to
“RM”?
P. 8
White-balance adjustment will
not complete.
Are the color temperature filters and lighting conditions appropriate?
Does the object have colors?
P. 18
The tally lamp does not light. Is the tally system of the RM-P210 compatible with that of the
camera system?
The RM-P210 has been set at the factory in the “make contact
mode”. If it is required to set it to the “voltage supplied mode”, the
setting of the internal circuitry should be changed; consult your
nearest JVC-authorized service agent. (The modification will then
be carried out with charge.)
P. 14
White-balance adjustment
cannot be started.
Is the W.BAL switch set to A or B?
Is FAS or FAW ON (which is indicated by the lighting of the AUTO
lamp)?
P. 18
LCD display shows "---". The connected camera does not have the assigned function.
Check the camera functions again and assign the proper
functions to the F1 to F4 keys.
P. 25
Intercom is not possible. Is the headset impedance suitable? (Earphone: 50 W to 300 W/
1 kHz. Microphone: Carbon).
P. 14
Pressing the corresponding
button cannot start the
operation.
<EXT> is displayed on the LCD.
Functions that are not available on the camera cannot be
controlled.
Check the camera functions again.
Symptom PageCheck Points
Video
troubles
Control
troubles