5-2 Contents of the Function Menu Switches
5 SETTING OF THE FUNCTION MENU SWITCHES
FunctionScreens Items Set values
VTR mode 2 COUNT END [OFF]
setting 500
1000
9500
:
:
Sets the timing to process tape end at a specified counter value rather than at
the actual tape end. This menu switch setting is effective in the 48H to 240H
Record modes. For the 6H to L30H modes, set with <REC REMAIN>. The
following operations are executed at the timing set with this menu switch.
The tape end signal is output from the rear panel's [TAPE END] terminal.
The series recording signal is output from the rear panel's [CLOCK/SERIES
OUT] terminal (with the TERMINAL SEL 1> function menu switch set to
"SERIES").
The tape end buzzer sounds (with the <TAPE END BUZZER> function menu
switch set to "ON").
"End" is shown on the counter display.
OFF: Executes tape end processing at the actual tape end.
5000 - 9500: Executes tape end processing at the set tape counter value.
To determine the set tape counter value according to the tape length, refer to
the table on page 53.
Alarm/sensor ALARM REC [OFF]
recording mode ON
setting
SENSOR REC [OFF]
ON
REC MODE [6H]
18H
30H
Turns the sensor recording function on or off. Sensor recording is enabled in
the Stop mode. An index code (VISS signal) is also recorded at the start point of
sensor recording.
OFF : Sensor recording is disabled.
ON : When an alarm signal is input to the rear panel's [ALARM IN] terminal in
the Stop mode. This unit automatically starts recording in the specified
Record mode.
Selects the recording mode for alarm recording or sensor recording.
6H : Recording is executed in the 6H(EP) mode.
18H : Recording is executed in the 18H mode.This value is not selected when
the <DURATION> function menu switch is set to "5 sec".
30H : Recording is executed in the 30H mode. This value is not selected when
the <DURATION> function menu switch is set to "5 sec" or "15 sec ".
Set the operation mode at tape end during recording in the case when alarm or
sensor recording is executed even once.
STOP : Stops at tape end.
REW : Rewinds the tape automatically and stops.
REPEAT : Rewinds the tape automatically to the beginning and restarts
recording.
EJECT : The tape is ejected.
DURATION 5
15
30
60
120
[180]
TAPE END
MANUAL
TAPE END [STOP]
MODE REW
REPEAT
EJECT
BUZZER [OFF]
ON
This screen is displayed on the on-screen setting screen only when the (optional) RS-232C board SA-K97U is installed.
RS-232C
parameter
setting BAUD RATE 1200
2400
4800
[9600]
Select the RS-232C data transfer speed from 1200 bps, 2400 bps, 4800 bps or
9600 bps.
Selects whether or not the alarm buzzer sounds during alarm or sensor
recording.
OFF : The buzzer does not sound.
ON : The buzzer sounds.
Selects the recording duration for alarm recording or sensor recording.
5 ..... 180 : Alarm or sensor recording is performed for the time specified (5 sec.
to 180 sec.).
5 sec is not selected when the <RECMODE> function menu
switch is set to "18H".
5 or 15 sec is not selected when the <REC MODE> function menu
switch is set to "30H".
TAPE END: Alarm or sensor recording continues until the tape ends.
MANUAL : Alarm or sensor recording continues for as long as alarm signals
are input.
Set to this position when specifying the alarm recording time with a
switcher.
Turns the alarm recording function on or off.
Alarm recording is enabled only in the Timelapse Record mode.
An index code (VISS signal) is also recorded at the start point of alarm
recording as an alarm cue signal.
OFF : Alarm recording is disabled.
ON : This unit enters the specified Record mode,
when an alarm signal is
input to the rear panel's [ALARM IN] terminal during timelapse recording.