Maxtor 773W V1.0 DVR User Manual


 
12
(PIP)
FULL SCREEN CAM 1
PIP SCREEN CAM 2
POSITION D/R
(DWELL)
NORM ALARM
CAM1 01 01
CAM2 01 01
CAM3 01 01
CAM4 01 01
3. REC IPS
Select the images per second of recording during an ALARM.
The options are as following:
NTSC30158421
PAL25126321
4. QUALITY
There are four quality settings during an alarm.
ALARM : BASIC, BEST, HIGH, NORMAL.
5. RECORD MODE
There are three recording settings : QUAD-FRAME, QUAD-FIELD,
MULTIPLEX.
DWELL
1. NORM
To set up the DWELL time period that each channel auto sequentially shows on call
monitor. The level is from 1 to 15 Sec or OFF.
2. ALARM
To set up the DWELL time period when alarm input is triggered.
The level is from 1 to 15 Sec or OFF.
PIP
1. FULL SCREEN
To set up the full screen background picture display.
2. PIP SCREEN
To set up the picture with a 1/9 size screen insert.
3. POSITION
There are six position settings : D/L, D/M, D/R, U/L, U/M, U/R.
(ALARM)
ALARM ENABLE YES
ALARM DURATION 15 MIN
RECORD IPS 30
QUALITY NORMAL
RECORD MODE QUAD-FRAME
ALARM
1. ALARM ENABLE
Alarm will be triggered by event occurrence when the setting is YES.
2. ALARM DURATION
Set the reaction time which was determined by how long the alarmmode
responded to a buzzer. Default setting is 10 sec. Options are 10 Sec, 15 Sec, 20
Sec, 30 Sec, 1 MIN, 2 MIN, 3 MIN, 5 MIN, 10 MIN, 15 MIN, 30MIN, ALWAYS, AUTO.
NOTE : 1. Video loss, Alarm and Motion messages is shown like the Alarm Duration time is.
2. When the setting is AUTO, the alarm duration time is based on the setting of the external
alarm device.
3. During ALARM DURATIONS setting time, users can restart ALARM/MOTION function by
pressing both ENTER+ STOPbuttons.