Mitsumi electronic AJ65BT- 64DAV/DAI TV Converter Box User Manual


 
5. PROGRAMMING MELSEC-A
5-7
*1: When making remote device station initialization procedure registration to multiple stations,
correct the program within the dotted line 1) as shown below.
[System configuration]
[Corrected program]
RX(m+1)B and RX(n+1)B are remote READY.
RX(m+1)8 and RX(n+1)8 are initial data processing request flags.
Insert the remote READY and initial data processing request flags for all the stations, to which the