E-19
Basic operation (Continued)
3) M.PED volume
When the volume operation is enabled, the
unit operates in the absolute value mode
where the value is fixed in accordance with
the position of the volume. The value will be
“0” by clicking the center.
The variable amount is within a range
between the minimum value of –200 and the
maximum value of +200 with the center value
of 0.
Operation of the scene file
The unit has five sets of scene files and is
capable to storing the current settings as a scene
file or loading the stored settings.
It is also possible to store/call scene files using
the SD memory card. For details, refer to
“Saving/Loading of scene files onto the SD
memory card” (page 21).
1) Operation of the scene file
When the lamp of the RECORDER ENABLE
button is off, the scene files are operated
using the seven buttons on the top right side
of the unit.
Storing: Select a file number to store using
buttons 1 to 5 (blue letters). When
the button is pressed, the button
lamp will flash. If the SAVE (blue
letters) button is pressed in this
state, the SAVE button lamp will
also flash. To store the file, press
the SAVE button again. When the
store operation is finished, the
lamp of the button for the stored file
number turns on.
When the lamps for buttons 1 to 5
are flashing, press the button or
leave for 10 seconds or more to
release the selection.
Loading: Select a file number to load using
buttons 1 to 5 (blue letters). When
the button is pressed, the button
lamp will flash. If the LOAD button
is pressed in this state, the
selected file will load. At this time,
the lamp of the VR ACTIVE button
flashes, the operation mode of the
volume set in the unit menu is
ignored, and the unit is in the
relative value mode.
AJ-RC10G.book 19 ページ 2006年7月26日 水曜日 午前9時25分