E-25
Menu item (Continued)
FLARE
<Note>
When the BLACK volume is assigned for flare
adjustment, it must be set in BLACK-VR-CONTROL,
BLACK-VR-MODE, and BLACK-VR-RANGE. When
“FLR” is selected in the BLACK-VR-CONTROL item, the
flare can be adjusted by using the BLACK volume.
Switching between the absolute value mode and the
relative value mode of the volume can be set in the
BLACK-VR-MODE item, while switching of the variable
range can be set in the BLACK-VR-RANGE item. When
the absolute value is selected in the BLACK-VR-MODE
item or the lamp of the VR-ACTIVE button is turned on,
R FLAR/G FLAR/B FLAR items cannot be adjusted
using the rotary encoder. They must be adjusted with
the BLACK volume.
GAMMA
WHITE
<Note>
When the absolute value is selected in the GAIN-VR-
MODE item, or the lamp of the VR ACTIVE button is
turned on, the R GAIN/G GAIN items cannot be
adjusted using the rotary encoder. They must be
adjusted using the GAIN volume.
is the factory setting mode.
Layer
Item
Variable
range
Contents description
Storage
1
RFLAR
–100
:
+100
To set the flare for Rch
Yes
GFLAR
–100
:
+100
To set the flare for Gch
Yes
BFLAR
–100
:
+100
To set the flare for Bch
Yes
2
FLAR-
CORRECT
ON
OFF
To set ON/OFF of the
flare correction
Yes
Layer
Item
Variable
range
Contents description
Storage
1
RGAM
–15
:
+15
To set the gamma for
Rch Yes
MGAM
0.30
:
0.75
To set the master
gamma Yes
BGAM
–15
:
+15
To set the gamma for
Bch Yes
2
GAMMA-
MODE-SEL
HD
SD
F-LIKE1
F-LIKE2
F-LIKE3
To select the gamma
Yes
3
GAMMA-
CORRECT
ON
OFF
To set ON/OFF of the
gamma correction
Yes
Layer
Item
Variable
range
Contents description
Storage
1
RGAIN
–200
:
+200
To set the Rch gain
Yes
BGAIN
–200
:
+200
To set the Bch gain
Yes
2
FILTER-INH
ON
OFF
To select whether the
filter has data for the
AWB memory (Ach,
Bch) or not, for the
respective filters
independently
ON: Data are held in
two memory
locations (Ach,
Bch) regardless
of the filter.
OFF: The respective
filters hold data.
Yes
3
SKLS-AWB
OFF
FAST
NORMAL
SLOW1
SLOW2
SLOW3
To turn on the shock-
less AWB (FAST/
NORMAL/SLOW1/
SLOW2/SLOW3)
Yes
AWBAREA
25%
50%
90%
To switch the AWB
detection area Yes
4
GAIN-VR-
MODE
ABS
REL
To select whether the
GAIN volumes for R
and B are operated
using the absolute
value or the relative
value
ABS: Absolute value
REL: Relative value
Yes
5
GAIN-VR-
RANGE
MIN
NORM
MAX
To switch the variable
range of the GAIN
volumes for R and B
MIN:
n
50
NORM:
n
100
MAX:
n
200
Yes
AJ-RC10G.book 25 ページ 2006年7月26日 水曜日 午前9時25分