Panasonic AJ- G Universal Remote User Manual


 
E-32
ENGLISH
Connection cable
A 10 m connection cable is attached to the unit. To extend the cable, use the optional dedicated cable.
If several 10 m cables are connected in tandem, the power supply may be unstable due to voltage
drops etc.
In an emergency, apply a higher voltage within a range from 11 V to 17 V for the power supply of DC 12
V to the camera recorder. If the input voltage to the unit is 8 V or less, operation becomes unstable.
Refer to the following. A twisted-pair cable must be used for the control line of the 10-pin cable.
Attenuation of the coaxial cable must be set to around –6 dB at maximum in 10 MHz.
Confirmation of software version
The software version for this unit can be confirmed in “VERSION” under SYSTEM in the unit menu.
Confirm for questions.
1
2
3
4
5
6
7
8
9
10
1
2
3
4
5
6
7
8
9
10
Camera recorder side
HR10A-10P-10P (Hirose Electric)
Controller side
HR10A-10P10S (Hirose Electric)
Twisted pair
Twisted pair
CAM DATA (H)
CAM DATA (C)
CAM CONT (H)
CAM CONT (L)
ECU_ON
Video output
GND (Video)
Standby
+12 V (IN)
GND
Connector GND
CAM DATA (H)
CAM DATA (C)
CAM CONT (H)
CAM CONT (L)
ECU_ON
Video input
GND (Video)
Standby
+12 V (IN)
GND
Connector GND
1.5C - 2V
3
h
or less
3
h
or less
AJ-RC10G.book 32 ページ 2006年7月26日 水曜日 午前9時25分