Panasonic AJ-D250P VCR User Manual


 
56
RS-232C
$
Query control commands
Sends data of computer Return data from VTR Description of command
[STX] QCE [ETX] [STX] CTEdata [ETX]
data = hhmmssff
hh = 00
23: Hours
mm = 00 59: Minutes
ss = 00 59: Seconds
ff = 00 29: Frames
Queries the time data which was preset in the TCG.
[STX] QCS [ETX] [STX] CTSdata [ETX]
data = hhmmssff
hh = 00 23: Hours
mm = 00 59: Minutes
ss = 00 59: Seconds
ff = 00 29: Frames
Queries the TCG’s time data.
[STX] QCT [ETX] [STX] CTdata [ETX]
data = mm
mm = FR: Regeneration mode
RP: REC RUN mode
FP: FREE RUN mode
VR: External VITC mode
Queries the mode in which the TCG is to be used.
[STX] QCW [ETX] [STX] CTMm [ETX]
m = 0: REC RUN mode
1: FREE RUN mode
2: Regeneration mode
3: External VITC mode
Queries the mode in which the TCG is to be used.
[STX] QCZ [ETX] [STX] CTZm [ETX]
m = 0: Read NG
1: Read OK
Queries the TCR read status.
[STX] QDF [ETX] [STX] DFCm [ETX]
m = C: CTL mode
T: TC mode
U: UB mode
R: REMAIN mode
Queries the display mode of the counter display.
[STX] QCF [ETX] [STX] CDm [ETX]
m = N: Drop frame mode
F: Non-drop frame mode
Queries the drop frame mode.
[STX] QCM [ETX] [STX] CHMm [ETX]
m = 1: 12-hour mode
2: 24-hour mode
Queries whether the CTL display is in the 12-hour mode or
24-hour mode.
[STX] QCP [ETX] [STX] CVPdata [ETX]
data = ppqq
pp = Insertion line 1
qq = Insertion line 2
Queries the setting of the two lines in which the external
VITC signal is to be inserted.
[STX] QCR [ETX] [STX] CRNm [ETX]
m = 0: TC & UB
1: TC
2: UB
Queries the REGEN (regeneration) signal when the TCG
(time code generator) is set to the regeneration mode.
[STX] QCU [ETX] [STX] CURdata [ETX]
data = U
7
U
6
U
5
U
4
U
7
U
3
U
2
U
1
U
0
Queries the user’s bit data of the TCR.