Panasonic WJ-RT208 DVD Recorder User Manual


 
17
Connections with any Existing Network System
Connections with a Broadband WAN Network
Caution: The number of clients that can be connected to each WJ-RT208 is defined in the next table. According to differences
in the network communication protocol, the number of clients that can be connected can differ. In the next table, the num-
ber of clients that can be connected is defined for the TCP/UDP protocol and the MCAST protocol, independently of each
other.
Windows
xp
Microsoft
PC/AT Compatible
Windows
xp
Microsoft
PC/AT Compatible
LAN cable
(Not provided: 10BASE-T/100BASE-Tx, Category 5, Straight)
HUB/Router
IP Address: 192.168.0.1
Subnet Mask: 255.255.255.0
LAN
IP Address: 192.168.0.88
Subnet Mask: 255.255.255.0
Gateway Address: 192.168.0.1
IP Address: 192.168.0.x (x except 0, 1, 88, 255)
Subnet Mask: 255.255.255.0
Gateway Address: 192.168.0.1
ERROR
ALARM
HDD
TIMER
OPERATE
1 2 3 4 5
6 7 8 90
MENU
ESC
ALARM
RESET
SEQUENCESTILL
PAUSE REV FWD SKIP
STOP PLAY REC
COPY 2
SET
Digital Disk Recorder WJ-RT
208
208
WAN
Windows
xp
Microsoft
PC/AT Compatible
Server Port: 2000 (changeable)
Alarm Port: 4000 (changeable)
Forward (WAN DVR)
UDP Port: 9998 (fixed)
TCP Port: 2000 (depends on the
recorder settings)
Broadband router A
Forward (WAN PC)
UDP Port: 999 (fixed)
TCP Port: 4000 (depends on the
recorder settings)
Broadband router B
ERROR
ALARM
HDD
TIMER
OPERATE
1 2 3 4 5
6 7 8 9 0
MENU
ESC
ALARM
RESET
SEQUENCESTILL
PAUS E R EV FWD SKIP
STOP PLAY REC
COPY 2
SET
Digital Disk Recorder WJ-RT
208208
Notes:
1. Broadband router A can only connect one WJ-RT208. (Each WJ-RT208 should
be assigned a Global IP address.)
2. Broadband router B can only connect one PC/AT compatible machine.
(Each compatible machine should be assigned a global IP address.)
User type TCP/UDP MCAST
Manager 1 person 1 person
8 persons Unlimited in the same subnet
1 person 1 person
4 persons Frame play not available
1 person 1 person
Remote monitoring
Remote playback/net backup
Frame play
Remote talk