Pelco TLR2096 VCR User Manual


 
Pelco Manual C651M (7/99) 31
8.1.2 Record Check Function
When the VCR is recording, press the PLAY button for more than 1.5 seconds and
then release. The tape rewinds a little and then plays back the recording just made.
When the tape reaches the spot where you pressed the PLAY button, the VCR
returns to record mode.
8.1.3 Audio Recording
Either apply the specified line input signal to the AUDIO IN connector or connect
the microphone to the MIC IN jack. If both are connected, the microphone is given
priority.
Normal sound is played back only when a tape recorded in 2H, 6H, or L18H mode
is played back in its respective mode.
The longer the recording time mode, the worse the sound quality becomes. In L18H
mode, the sound quality is such that speech can be heard.
8.1.4 Repeat Recording
When TAPE END on the First Time Set Up menu is set to REPEAT or ALARM•PROT
and the repeat recording mode is set (the REPEAT indicator is lit), the tape will
automatically rewind to the start when the end of the tape is reached. Recording
will begin again.
Table D shows what automatically happens when the tape ends during recording.
Table D. When Tape End Is Reached
STOP REWIND REPEAT ALARM•PROT
NOTE:
On ALARM•PROT mode,
a tape with alarm recordings can
be used for repeat recording by
ejecting and re-inserting the tape.
The tape rewinds
automatically to
the beginning
and recording
resumes.
When there are
alarm recordings
on tape.
The tape
stops.
The tape rewinds
automatically to
the beginning and
then stops.
The tape rewinds
automatically to
the beginning
and recording
resumes.
The tape stops
When there are no
alarm recordings
on tape.
8.1.4.1 Number Of Tape Uses (Repeat Recording
Times)
Displays the number of times a tape has been used when the TAPE END setting is
set to REWIND, REPEAT, or ALARM•PROT.
1. Press the DISPLAY button. The Main menu will appear.
2. Turn the JOG dial to select MAINTENANCE and turn the SHUTTLE ring to the
right. MAINTENANCE will appear on the display. REPEAT REC TIMES indi-
cates how many times a tape has been recorded on.
The number of tape uses increments by one when the tape ends.
The number of tape uses is kept even if the AC power is disconnected,
provided the backup battery is fully charged.
The number of tape uses is reset when you replace the current tape with
another.
3. Press the DISPLAY button. The time will be displayed.
<MAINTENANCE >
POWER LOSS LIST
ALARM LIST
ALL MENU INITIALIZE
POWER LOSS LIST CLEAR
ALARM LIST CLEAR
<REPEAT REC TIMES> 0
<ELAPSED TIME> 0H