Pelco TLR2096 VCR User Manual


 
Pelco Manual C651M (7/99) 35
8.2.3 Avoid Mistakes When Using The Timer
Refer to Table G if you get an error when pressing the TIMER REC button.
A tape is not inserted.
A tape is loaded with the
erasure prevention tab
removed.
Date, time, or timer
recording time is not set.
A menu is being
programmed.
Table G. Timer Recording Troubleshooting
SYMPTOM FAULT ACTION
TIMER REC indicator
flashes.
1. Press the TIMER REC
button.
2. Correctly set the timer
program.
3. Press the TIMER REC
button and confirm the
TIMER REC indicator
( ) is illuminated.
8.3 ALARM RECORDING
You can switch from all recording modes to the 2H-96H alarm recording mode by
applying an alarm signal to the SET IN (alarm input) terminal on the rear panel.
You can switch to alarm recording by applying the alarm input signal from the
alarm sensor during recording in 2H, 6H, L18H, 72H, or 96H.
Set the alarm recording mode and alarm recording period in the Recording
Set Up menu. Refer to Section 6.7 for instructions.
The index signal is automatically recorded when alarm recording begins (IN-
DEX indicator flashes on the fluorescent display).
To record the index signal, the first 15 seconds of the alarm recording are in
2H or 6H mode.
If another alarm input signal is applied to the SET IN (alarm input) terminal
while the index signal is being recorded (for 15 seconds), a new alarm record-
ing will not be triggered.
ALARM SET INPUT
2H - 96H
RECORDING
2H - 96H
RECORDING
2H or 6H
RECORD-
ING
2H -L18H
RECORDING
15sec
NORMAL mode
NORMAL mode
ALARM mode
ALARM INPUT
Figure 22. Switching From Normal To Alarm Mode And Back