Planet Technology DVR-1670 DVR User Manual


 
Page 62
First select one camera, then select one of following PTZ linkage
z PresetSet the flag as “9” to enable preset, in the preset number edit box and input one
preset number that has been setup already. Please refer to chapter 5.15 for preset setup.
z SequenceSet the flag as “9” to enable sequence and input one sequence number that
has been setup already. Please refer to chapter 5.15 for sequence setup.
z CruiseSet the flag as “9” to enable cruise. Please refer to chapter 5.15 for cruise setup.
Press “Confirm” button to save and return “Alarms” menu. Press “Cancel” button orESC
key to abort and return “Alamrs” menu.
NotePlease make sure that the PTZ you are using can support preset, sequence and cruise
functions. One external alarm input can trigger many cameras PTZ linkage.
Step 9Copy the parameters to other external alarm input
You can copy the parameters of current alarm input to other external input.
Step 10Save setup
In “Alarms” menu, press “Confirm” button to save the parameters. Press “Cancel” button or
ESCkey to abort.
Alarm relay output setup
Step 1In “Alarms” menu, use【↑】【↓】keys to select one alarm output.
Step 2Select delay time
The delay time is when the alarm is disappeared, the alarm output will continue output time.
The delay time options are5 Seconds, 10 Seconds, 30 Seconds, 1 Minute, 2 Minutes, 5
Minutes, 10 Minutes and Manual Stop. If you select “Manual’ option, the alarm output will
not stop until you press “Clear Alarm” button in “Utilities” menu. So the actual alarm output
time is made up of alarm input time and this delay time.