Planet Technology DVR-1670 DVR User Manual


 
Page 66
PTZ menu description
Select channelSelect one PTZ camera.
RS-485 parametersIncluding baudrate, data bit, stop bit, parity, flow control, etc. These
parameters must be the same as those of PTZ. Protocol.
PTZ addressEach PTZ has one different address.
PTZ typeDVR had the following PTZ protocolYouLi, LinLin-1016, LinLin-820, Pelco-p,
DM DynaColor, HD600, JC-4116, Pelco-d WX, Pelco-D, VCOM VC-2000,
NetStreamer, SAE/YAAN, Samsung, Kalatel-312, CELOTEX, TLPelco-p,
TLHHX-2000, BBV, RM110, KC3360S, ACES, ALSON, INV3609HD, Howell,
Tc Pelco P, Tc Pelco D, AUTO-M, AUTO-H, ANTEN, CHANGLIN, DeltaDome,
XYM-12, ADR8060, EVI-D30, DEMO-SPEED, DM-PELCO-D, ST832,
LC-D2104, HUNTER, A01, TECHYIN, WEIHAN, LG, D-MAX, Panasonic,
KTD-348, infinova, PIH-7625, LCU, DennarDome, etc. Other PTZ protocols
will be added with the new firmware.
NoteIn DVR “PTZ” menu, if you select Pelco-P protocol, when you setup PTZ address,
please plus or minus one compared with Camera ID. For example, if camera ID is 2,
the DVR PTZ address is set as ID 3.
Preset setupPreset is using one number to represent the camera’s position, zoom, focus and
iris. Move “Active Frame” to “Setup” button on the right side of “Preset” item, press
ENTERkey to enter into preset setup menu. You can save 128 preset numbers. Please
make sure the PTZ support preset function before you setup preset.
Sequence setupEach sequence is made up of several curise points. Each cruise point
includes one preset number, dwell time and dwell speed. Please make sure the PTZ you are
using can support sequence function before you start to setup. You can save 16 sequnece.