Runco DR-300C CRT Television User Manual


 
29
COMMAND PARAMETER (min/max) Value stored? DESCRIPTION
!STORE NA YES Stores the current set of values
(all values) into non-volatile
memory
!RESTORE NA YES Restores the stored values
!FACTORY NA YES Restores all values to factory
default levels
!STATUS NA NA Asks the Controller to provide
the hardware information,
current values and system status
to the automation system
!RESTART NA NO Restarts the PFP Controller
(same as turning it on and off)
!ECHO NA NO Enables the Controller to echo
back commands and values to
the automation system
!NOECHO NA NO Disables the PFP Controller's
character echoing
!INSTALLMODEOFF NA NA Disables the Installation menu
(removes it from the main menu)
!INSTALLMODEON NA NA Enables the Installation menu
(enables it on the main menu)
!SERVICEMODEON NA NA Enables the service mode
!SERVICEMODEOFF NA NA Disable the service mode
RGAIN -64/64 NO Adjust the Red Gain of image
GGAIN -64/64 NO Adjust the Green Gain of image
BGAIN -64/64 NO Adjust the Blue Gain of image
ROFFSET -64/64 NO Adjust the amount of Red in the
dark areas of the image
GOFFSET -64/64 NO Adjust the amount of Green in
the dark areas of the image
BOFFSET -64/64 NO Adjust the amount of Blue in
the dark areas of the image