Sanyo TLS-9072 VCR User Manual


 
NORMAL RECORDING
Recording Check
The image being recorded can be checked.
1 During recording, press the PLAY (REC CHECK)
button.
ø
The tape will be rewound and then played back.
The VCR will then return to the previous
recording mode.
NOTE:
X During recording check operations, recording is
suspended momentarily.
Clog Detection
This VCR is equipped with a clog detection function.
The recording quality is monitored automatically. When
the heads are dirty and the recording quality deteriorates,
the output at the WARNING OUT terminal becomes 0V
(Low), the “m” indicator flashes on the digital display, and
the buzzer sounds.
If in the (SET UP 3) menu, CLOG DETECT. is set to “N”,
the recording quality is not monitored.
NOTES:
X To cancel the “m” indicator display and reset the
WARNING OUT terminal output, press the STOP
button.
X Clog detection is not possible if recording in 2-hour
mode.
Setting the Mode at the End of the Tape
In the (SET UP 3) menu, you can set the mode of the
VCR mode when the tape reaches the end during
recording.
1 Press the MENU button until the (SET UP 3) menu is
displayed.
@@@@@@@<SET@UP@3>
*ALARM@MODE@@@@@@@Y1
*ALARM@DURATION@@@20S
*TAPE@IN@MODE@@@@@STOP
*TAPE@END@MODE@@@@REW
*TAPE@END@OUT@@@@@-3M
*CLOG@DETECT.@@@@@Y
2 Press the * (or +) button, until the “TAPE END
MODE” setting is flashing.
3 Press the l (or j) button to set the desired mode.
X Setting when the REPEAT REC switch is set to the
“OFF” position.
REW. . . . . . . Rewinds the tape to the beginning,
then goes to stop mode
STOP . . . . . . Goes to stop mode
EJECT . . . . . The cassette is ejected
X Setting when the REPEAT REC switch is set to the
“ON” position.
R1. . . . . . . . . Autorepeat recording mode is
automatically canceled if there was
an alarm trigger
R2. . . . . . . . . Autorepeat recording mode is
active even if there was an alarm
trigger
4 Press the SEARCH/AUDIO ON button to save the
setting.
RC4Q/NA2 (TLS-9072 GB) Thu. Sept., 07/2000
18 English