Selecting the REBOOT Method
DIP-switch 5 selects between the No Answer REBOOT and the On-Hook REBOOT methods:
5|OFF On-Hook
REBOOT Method
5|ON No Answer
REBOOT Method
DIP-switches 5 and 7 select the +Aux Port (Secure)
REBOOT method:
5|ON 7|ON
Ring-Count Select
DIP-switch 6 selects the minimum Ring-Count required to initiate a REBOOT when rings cease.
6|OFF Ring-Count required = Eight (8)
6|ON Ring-Count required = One (1)
Off-Hook
REBOOT Option
DIP-switch 8 enables the maximum 2-hour Off-Hook limit. Any off-hook condition exceeding 2 hours will initiate an
immediate
REBOOT.
8|OFF Off-Hook
REBOOT Option - Disabled
8|ON Off-Hook
REBOOT Option - Enabled
Technical Note: Because the telephone company RING signal is not always synchronized between the calling and
receiving parties, it is best to allow one extra ring when counting the rings to effect a reboot (1 or 8 rings). For example,
if the eight (8) ring option is selected, allowing the line to ring nine (9) times should guarantee that the required minimum
number of rings have occurred at the target end of the call.