Sharp XG - P10XU Projection Television User Manual


 
E-54
Appendix
Wired Remote Control Terminal Specifications
Specifications of wired remote control input
ø3.5 mm minijack
External: ם5 V (1 A)
Internal: GND
Function and transmission codes
POWER ON
POWER OFF
VOLUME מ
VOLUME ם
MUTE
MENU
LENS
TOOLS
BLACK SCREEN
ENTER
UNDO
1
2
3
4
5
6
7
8
9
10
11
1
1
1
1
1
1
1
1
1
1
1
C1
0
0
0
0
0
0
0
0
0
0
0
C2
1
1
1
1
1
1
1
1
1
1
1
C3
1
1
1
1
1
1
1
1
1
1
1
C4
0
0
0
0
0
0
0
0
0
0
0
C5
0
0
1
0
1
0
1
0
1
1
1
C6
1
1
0
0
1
0
1
1
0
1
0
C7
1
1
1
1
1
1
0
0
0
1
0
C8
0
0
0
0
0
0
1
1
1
0
1
C9
1
1
1
1
1
0
0
0
0
1
1
C10
0
0
0
0
0
0
0
1
1
0
0
C11
1
0
0
0
0
1
0
1
1
1
1
C12
0
1
0
0
0
1
1
1
0
0
0
C13
1
1
1
1
1
1
1
1
1
1
1
C14
0
0
0
0
0
0
0
0
0
0
0
C15
No. Control Item System Code Data Code External Code
(Function)
INPUT
FREEZE
ENLARGE
AUTO SYNC
ADJUST
ADJUST ƒ
ADJUST ß
ADJUST ©
RESIZE
GAMMA
12
13
14
15
16
17
18
19
20
21
1
1
1
1
1
1
1
1
1
1
C1
0
0
0
0
0
0
0
0
0
0
C2
1
1
1
1
1
1
1
1
1
1
C3
1
1
1
1
1
1
1
1
1
1
C4
0
0
0
0
0
0
0
0
0
0
C5
1
1
1
0
0
1
0
1
0
0
C6
1
0
0
1
0
0
0
1
1
0
C7
0
1
1
0
1
1
0
1
1
0
C8
0
1
1
1
1
1
0
1
1
0
C9
1
0
0
1
1
1
1
0
1
0
C10
0
0
1
1
0
0
0
0
0
0
C11
0
0
1
1
0
0
1
1
1
1
C12
0
1
0
1
1
1
0
0
0
0
C13
1
1
1
1
1
1
1
1
1
1
C14
0
0
0
0
0
0
0
0
0
0
C15
No. Control Item System Code Data Code External Code
(Function)
To operate the mouse, left-click and right-click functions
through the wired remote control input, connect the cable
from the WIRED REMOTE control input terminal on the
projector to the remote control. The codes for these functions
are complex and are, therefore, not listed here.
Wired remote control function code
10110********10
C1 System Code C5 C6 Data Code C13 C14 C15
System codes C1 to C5 are fixed at 10110.
Codes C14 and C15 are reverse confirmation bits, with 10
indicating Front and 01 indicating Rear.
LSB MSB
Sharp remote control signal format
Transmission format: 15-bit format
Wave form of output signal: Output using Pulse Position Modulation
DDDDDD
DDDDDDD
67.5 ms 67.5 ms
010
D
0001
T
0T1
t
t
26.4 µs
t ס 264 µs
T0 ס 1.05 ms
T1 ס 2.10 ms
Transmission control code
15 bit
Example of Reverse D to
Pulse carrier frequency ס 455/12 kHz
Duty ratio ס 1:1
C1 C2 C3 C4 C5 C6 C7 C8 C9 C10 C11 C12 C13 C14
System Address
D to D Common Data Bit Reverse in D
Function Key Data Bit
Data
Expansion
Data
Deter-
mination
Mask
C15
C1
1
DC2
0
C3
1
C4
1
C5
0
C6
1
C7
0
C8
0
C9
0
C10
0
C11
0
C12
0
C13
0
C14
1
C15
0
C1
1
DC2
0
C3
1
C4
1
C5
0
C6
0
C7
1
C8
1
C9
1
C10
1
C11
1
C12
1
C13
1
C14
0
C15
1