35
E
SCREEN menu
Function
Command Direction
Parameter Reply Control/Response contents *1
*2
(A) (B)
AUTO ASNC W 1 When the input mode is PC D-SUB, PC RGB.
-
○ ○
CLOCK CLCK WR 0-1200 0-1200 When the input mode is PC D-SUB, PC RGB.
Varies depending on the signal.
PHASE PHSE WR 0-63 0-63 When the input mode is PC D-SUB, PC RGB.
POSITIONING POSITION OF
THE LONGEST
DIRECTION
HPOS WR 0-100 0-100 0-800 on PC D-SUB, PC RGB.
Varies depending on the signal.
POSITION OF
THE SHORTEST
DIRECTION
VPOS WR 0-100 0-100 0-200 on PC D-SUB, PC RGB.
Varies depending on the signal.
SIZE SIZE OF THE
LONGEST
DIRECTION
HSIZ WR 0-100 0-100
SIZE OF THE
SHORTEST
DIRECTION
VSIZ WR 0-100 0-100
RESOLUTION
LONGEST
DIRECTION
RESOLUTION
HRES WR 300-1920 300-1920 When the input mode is PC D-SUB, PC RGB.
Only even numbers are valid for parameters.
Varies depending on the signal.
SHORTEST
DIRECTION
RESOLUTION
VRES WR 200-1200 200-1200
RESET ARST W 1
Controlling the Monitor with a PC (RS-232C)