— 22 —
KV-27FV16/29FV16/29FV16C/32FS12/32FS16
5-1. SETTING THE SERVICE ADJUSTMENT MODE
1. Standby mode (power off).
2.
Display Channel
5
Sound volume Powe
r
+
on the Remote Commander (press each button within a
second).
Service Adjustment Mode On
1. The CRT displays the item being adjusted.
SERVICE HSIZ 0
Disp.
(Item)
Item
Data
2. Press or on the Remote Commander to select an item.
3. Press
or on the Remote Commander to change the data.
4. Press
then to save into the memory.
Service Adjustment Mode Memory
1. Press then on the Remote Commander to
initialize.
SERVICE RESET
2. Turn set off then on to exit service adjustment mode.
SECTION 5
CIRCUIT ADJUSTMENTS
Carry out step 1 when adjusting
IDs 0–4 and when replacing
and adjusting IC003.
5-2. MEMORY WRITE CONFIRMATION METHOD
1. After adjustment, remove the power plug from the AC outlet,
then plug it in again.
2. Turn the power switch ON and set to service mode.
3. Call the adjusted items again to confirm they were adjusted.
5-3. ADJUSTMENT BUTTONS AND INDICATORS
ELECTRICAL ADJUSTMENTS BY REMOTE COMMANDER
Use the Remote Commander (RM-Y168, RM-Y169 or RM-Y171) to perform the circuit adjustments in this section.
NOTE: Test Equipment Required:
• Pattern generator
• Frequency counter
• Digital multimeter
• Audio oscillator
RM-Y171
MUTING
POWER
DISPLAY
1
4
8
3
5
6
ENTER
VOLUME