Sterling 882.000254.00 Home Theater Server User Manual


 
7/50D Plus or 7/50D Controller Chapter 3: Installation 19
10. Drive the two screws at the center points about halfway down; first on the latch side,
then the hinge side.
11. Continue to tighten the screws a little at a time until fully tightened; no more than 15
inch-pounds (5.6 N
m) of torque.
Note: You can only pierce the cable once. Once pierced, the KwikLock
connector must not be removed. This insures that the inner conductors
are not exposed to the elements.
Installing Inside KwikLink Connectors with Blank Caps
Once installed on the grey data cables, these connectors permit you to measure voltage in the
system so you can analyze how it is working. The system cannot work properly unless these
inside-mounted connectors have the blank (non-conductor) caps installed.
1. Lay the cable in the hinged base, noting the correct keyed profile; flat edge toward
the hinge, keyed edge toward the latch. Make sure that the cable is properly seated
inside.
2. Making sure that the cable is completely straight, carefully close the hinged
assembly, and apply firm, even pressure until the first latch locks into place.
Note: Make sure that the flat cable is completely straight before continuing!!
The latch has two catches; the first loosely holds the connector on the cable, the
second requires more pressure to close the connector tightly. The cable must be in the
correct position for the connector to close properly.
3. Drive the two screws at the center points about halfway down; first on the latch side,
then the hinge side.
4. Continue to tighten the screws a little at a time until fully tightened; no more than 15
inch-pounds (5.6 N
m) of torque.
Note: You can only pierce the cable once. Once pierced, the KwikLock
connector must not be removed. This insures that the inner conductors
are not exposed to the elements.
The system should now be properly terminated. You can now continue to install components
on the system.
Figure 4: Proper Termination Connections
ArmorBlock Mounting Plate Kit
AEC P t N A0556696
Inside KwikLink Connector
with Blank Cap
Inside KwikLink Connector
with Blank Cap
Dust Caps
Inside KwikLink Connector
with Blank Cap
Inside KwikLink Connector
with Blank Cap
ArmorBlock Mounting Plate Kit
Part No. A0556696
Standard KwikLink
Co
nn
ecto
r
s