4. OPERA
4. OPERA
TING PROCEDURE
TING PROCEDURE
4.1 POWERING ON
This DVR is built to be on at all times, and therefore should be connected to a surge
protected power bar (UPC power backup). Use the power bar's switch to turn the unit off
and on. This is especially important as loss of power while recording could possibly
damage the hard drive. Every time the DVR is powered on, it will auto-detect its
peripherals (self-testing, warm-up, auto detects the hard drive, etc). It will also detect all
video input signals. If it does not detect an input, (eg: no camera present) it will sound an
alarm. Press any button on the DVR to stop the alarm. There are 4 camera inputs and
channels. Disable the unused channels in the Camera Setup Menu to prevent the alarm
from activating every time the unit is powered on.
4.2 MONITORING MODE
Monitoring mode is the default mode after the DVR is powered on. It will display all 4
camera views. To display a specific camera, press the corresponding number. This will
place that camera's view on your entire screen. To display all cameras again, press the
Quad Display button. To start recording, press REC. To stop recording, press STOP.
To reset all DVR settings to their factory default settings (under quad or single display),
press the PAUSE button 5 times. The message ALL SETTING DATA IS INITIALIZED will
be displayed, and after the reset the default password will be set as 111111.
When the reset is completed, the message DVR RESET COMPLETED. TURN OFF AND
ON THE DVR will be displayed. Restart the DVR to continue.
4.3 RECORD MODE