ViewSonic CDE6500-L Flat Panel Television User Manual


 
33
Reply (Hex Format)
Name Length ID Command Type Command Value1 Value2 Value3 CR
Hex
0x38
0x30
0x35
0x72 0x62 0x30 0x36 0x37 0x0D
Example2: Get Brightness from TV-05 , but the Brightness command ID is error
and it is NOT in the command table.
Send (Hex Format)
Name Length ID Command Type Command Value1 Value2 Value3 CR
Hex
0x38
0x30
0x35
0x67 0XD3 0x30 0x30 0x30 0x0D
Reply (Hex Format)
Name Length ID Command Type CR
Hex
0x34
0x30
0x35
0x2D 0x0D
Get-function table
Set Function Length ID
Command
Type
Command
Value Range
(Three ASCII bytes)
Comments
Code (ASCII) Code (Hex)
Get-Contrast 8 g a 61 000 ~ 100
Get-Brightness 8 g b 62 000 ~ 100
Get-Sharpness 8 g c 63 000 ~ 100
Get-Color 8 g d 64 000 ~ 100
Get-Tint 8 g e 65 000 ~ 100
Get-Volume 8 g f 66 000 ~ 100
Get-Mute 8 g g 67 000: Off
001: On (muted)
Get-Input select 8 g j 6A 000~ See Set-function
table
Get-Power
status: ON/
STBY
8 g l 6C 001: ON
000: STBY
Get-Remote
control
8 g n 6E 000: Disable
001: Enable
002: Pass through
Gets RCU mode
status
Get-Power lock 8 g o 6F 000: Unlock
001: Lock
Get-Button lock 8 g p 70 000: Unlock
001: Lock
Get-Menu lock 8 g q 71 000: Unlock
001: Lock
Get-Setup
wizard
8 g s 73 000: Disable
001: Enable
Get-ACK 8 g z 7A 000 This command is
used to test the