Wegener Communications 4600 Home Theater Server User Manual


 
UNITY 4600 USERS MANUAL
800032-01 Rev. F 40 www.wegner.com
R type [page] (Continued)
[page]: This option can have a value of 1 to 40 and is only applicable for the group status report.
Indicates the page to be reported. If omitted, all eight pages are reported and scrolls off
the terminal screen.
With the R command, the user gets a combined report of unit non-volatile settings and status and
diagnostics for each item grouping (e.g., RF for all unit settings and all status diagnostics for carrier
acq/tracking). A Local Control Command (available from the terminal regardless of "Local Control
Enable/Disable" commands from the network).
RD group
group: Indicates group of status/diagnostic information to report, as follows:
AUD - Audio service diagnos.
AW - Alarm/Warning status
CA - Conditional Access diagnostics
DPI - Conditional Digital Program Insertion (DPI)
GL - Genlock system (if installed and applicable)
LAN - IP/Ethernet diagnostics
NTW - COMPEL
network control diagnostics
PRGMP - Program mapping at ASI output
MSC - Miscellaneous diagnostics
REC - Automated Recovery status
RF - Carrier Acquisition/Tracking diagnostics
RPA - Return Path diagnostics
SW - Software download/self-test status
TS - Transport Stream diagnostics
VID - Video service diagnostics
Expanded report on unit volatile diagnostic and status information. A Local Control Command (available
from the terminal regardless of "Local Control Enable/Disable" commands from the network).
RE state [number]
state: ON, OFF, or W
number: 1 or 2, or E1 thru En (for n-relay expansion option module, if installed) indicating the
affected user relay.
This non-volatile command sets the user (or expansion) relay addressed by number to the ON/OFF or
"Follow-Warn" (if 'W) state specified.
Note: The W value for the state parameter is only accepted for the native relays (1 or 2).
If state is specified, but number is omitted, then the command is applied to ALL installed relays, with one
exception. The exception is that the command to ALL relays will not be accepted by a native user cue
relay already set in the logical "Follow-warn" state. (It MUST be individually addressed to return it to the
ON or OFF non-volatile state. Entering this command without parameters shows the state of installed
relays.
Table 3.3: Command Directory for U4600 Terminal Commands