68 PDS • User’s Guide
4. Operation
Setup Menu
Remote Control — This function sets up the PDS for remote control.
Figure 4-44. Remote Control Submenu (sample)
For complete details, see “Appendix B” on page 129.
IP — The IP line is an information-only line that shows the current IP address in all
modes (with DHCP on or off). If an IP address has not been established (no
DHCP server found, or the network cable is not connected), the address reads
"000.000.000.000."
M — The M line is an information-only line that shows the MAC (hardware)
address of the unit's Ethernet port.
pÉêá~ä=pÉíìé
From the System Menu, select Serial Setup to display the Serial Setup Menu, which
enables you to set system RS-232 parameters for the serial port.
Figure 4-45. Serial Setup Menu (sample)
The following functions are available:
Baud — Use this function to set the baud rate.
~ Adjustment range: 9600, 38400, 57600 and 115200
~ Default: 115200
Parameters — This function is a combined setting of Parity, Data Bits and Stop
bits (in this order).
~ Adjustment range: N81, E71, O71, E72, O72
~ Default: N81
Handshaking — This is a status field for the hardware flow of the serial port.
~ Default: OFF (the only valid value)
By default, RTS/CTS and DSR/DTR are ignored.
Reset — Use this function to reset all serial values to their default settings.
REMOTE CONTROL
> Unit ID 25
IP 192.168.000.002
Status n/a
Connect OFF
Note
The PDS’s default IP address is 192.168.0.10
SERIAL SETUP
> Baud 115200
Parameters N81
Handshaking ON
Reset