![](https://pdfstore-manualsonline.prod.a.ki/pdfasset/e/00/e00d769b-ea41-4a4a-9bff-ae8c28769981/e00d769b-ea41-4a4a-9bff-ae8c28769981-bg73.png)
A.4 Commands
Appendix A-45
Sense
key
Additional
sense code
Additional
sense code
qualifier
Description
0 00 00 No-sense
2 00 00 Not ready
3 80 01 Jam
3 80 02 ADF cover open
3 80 03 Document chuter empty of paper
3 80 04 Detects job separation sheet
(See Appendix A.5)
4 80 01 Blown fuse for FB motor
4 80 03 Blown lamp fuse
4 80 04 Blown fuse for ADF motor
4 80 05 Mechanical alarm
4 80 06 Optical alarm
4 44 00 Abnormal internal target
4 47 00 SCSI parity error
5 00 00 Page end is detected before reading
(VGATE ON) when page end detection
is enabled.
5 1A 00 Parameter length illegal
5 20 00 Invalid command
5 24 00 Invalid field in CDB
5 25 00 Unsupported logical unit
5 26 00 Invalid field in parameter list
5 2C 02 Wrong window combination
5 2C 00 Command sequence error
6 00 00 UNIT ATTENTION
B 43 00 Message error
B 45 00 SELECT/RESELECT FAILURE
B 47 00 SCSI parity error
B 80 01 Image transfer error
l. Sense-key specific bytes: Bytes F to 11
This field is reserved on this scanner.
(X’00000000’ must not be expected.)