A SERVICE OF

logo

Scanner Interface
Appendix A-28
c. Removable medium (RMB) : Byte 1
This scanner does not support RMB. This scanner returns B’0’.
d. Device type qualifier: Byte 1
This scanner does not support this field. This scanner always returns B’0000000’.
e. ISO version, ECMA version, ANSI approved version: Byte 2
Indicates the version number of the governing standard. This scanner returns X’02’ (SCSI-
2).
f. Asynchronous event notification capability (AENC) : Byte 3
This scanner does not support this field, so it returns B’0’.
g. Response data format: Byte 3
Indicates the standard, and its version number, that governs the format of inquiry data. This
scanner returns B’0010’ (SCSI-2).
h. Additional length (n-4) : Byte 4
Specifies the number of bytes, from byte 5 to the last byte. This value will not change with
the allocation length value specified in CDB. This scanner returns X’5B’ (the 91 bytes from
byte 5 to byte 5F).
i. RelAdr, Wbus32, Wbus16: Byte 7
This scanner does not support RelAdr/ Wbus32/ Wbus16. This scanner returns B’000’.
j. SYNC (synchronous transfer) : Byte 7
This scanner returns B’1’ (“gsynchronous transfer supported” ).
k. Linked, cache, CMDQUE: Byte 7
This scanner does not support linked/cache/CMDQUE. This scanner returns B’000’.
l. sftRst (Soft Reset) : Byte 7
This scanner performs Hardware Reset. This scanner returns B’0’.
m. Vendor identification: Bytes 8 to F
Indicates the vendor of the logical unit in ASCII code. The vendor name is left- justified,
with the blank filled with spaces (X’20’). This scanner returns “FUJITSU”.
n. Product identification: Bytes 10 to 1F
Indicates the product name in ASCII code. The name is left-justified, with the blank filled
with spaces (X’20’). This scanner returns one of the following names:
Scanner type M3097DG
Scanner without option M3097DGdm
With IPC-2D option M3097DGdim
o. Product revision level: Bytes 20 to 23
Indicates the version number of the product in ASCII code. This number is left- justified,
with the blank filled with spaces (X’20’).