SPARC Enterprise M4000/M5000 Servers Product Notes 23
6542632 Memory leak in PCIe module if driver attach
fails.
There is no workaround. Check for the
availability of a patch for this defect.
6545685 If the system has detected Correctable Memory
Errors (CE) at power-on self-test (POST), the
domains might incorrectly degrade 4 or 8
DIMMs.
Increase the memory patrol timeout values
used via the following setting in
/etc/system:
set mc-opl:mc_max_rewrite_loop =
20000
6546188 The system panics when running hotplug
(cfgadm) and DR operations (addboard and
deleteboard) on the following cards:
• X4447A-Z, PCI-e Quad-port Gigabit
Ethernet Adapter UTP
• X1027A-Z1, PCI-e Dual 10 Gigabit Ethernet
Fiber XFP Low profile Adapter
There is no workaround. Check for the
availability of a patch for this defect.
6551356 The system panics when running hotplug
(cfgadm) to configure a previously
unconfigured card. The message "WARNING:
PCI Expansion ROM is not accessible" will be
seen on the console shortly before the system
panic. The following cards are affected by this
defect:
• X4447A-Z, PCI-e Quad-port Gigabit
Ethernet Adapter UTP
• X1027A-Z1, PCI-e Dual 10 Gigabit Ethernet
Fiber XFP Low profile Adapter
Perform cfgadm -c disconnect to
completely remove the card. After waiting at
least 10 seconds, the card may be configured
back into the domain using the cfgadm -c
configure command.
6556742 The system panics when DiskSuite can not
read the metadb during DR. This bug affects
the following cards:
• SG-XPCIE2FC-QF4, 4Gb PCI-e Dual-Port
Fibre Channel HBA
• SG-XPCIE1FC-QF4, 4Gb PCI-e Single-Port
Fibre Channel HBA
• SG-XPCI2FC-QF4, 4Gb PCI-X Dual-Port
Fibre Channel HBA
• SG-XPCI1FC-QF4, 4Gb PCI-X Single-Port
Fibre Channel HBA
Panic can be avoided when a duplicated copy
of the metadb is accessible via another Host
Bus Adaptor. Or you can apply patch 125166-
06.
TABLE 6 Specific Issues and Workarounds Concerning Solaris (Continued)
CR ID Description Workaround