A SERVICE OF

logo

SPARC Enterprise M4000/M5000 Servers Product Notes 25
6572593 fmdump(1M) may show wrong faulty
component when IOU hardware error occurs.
Check system status on XSCF.
6589833 The DR addboard command might cause a
system hang if you are adding a Sun
StorageTek Enterprise Class 4Gb Dual-Port
Fibre Channel PCI-E HBA card (SGXPCIE2FC-
QF4) at the same time that an SAP process is
attempting to access storage devices attached
to this card. The chance of a system hang is
increased if the following cards are used for
heavy network traffic:
X4447A-Z, PCI-e Quad-port Gigabit
Ethernet Adapter UTP
X1027A-Z1, PCI-e Dual 10 Gigabit Ethernet
Fiber XFP Low profile Adapter
There is no workaround. Check for the
availability of a patch for this defect.
6592302 Unsuccessful DR operation leaves memory
partially configured.
To recover, add the board back to the domain
with the addboard command, then retry the
deleteboard command.
TABLE 6 Specific Issues and Workarounds Concerning Solaris (Continued)
CR ID Description Workaround