![](https://pdfstore-manualsonline.prod.a.ki/pdfasset/7/06/7062a857-4e12-48c1-84f7-fd1d7785ead9/7062a857-4e12-48c1-84f7-fd1d7785ead9-bg75.png)
107
Basic Programming
Programming Stations/Sets Automatically
The AUTO PROGRAM function in Form 09, Desktop Device Assignments,
checks for unprogrammed circuits in the system and programs them as
follows:
• Extension numbers are automatically assigned according to a Bay,
Slot, Circuit address format “BSCC”, where
- B is the Bay number (1-8)
- S is the slot number (1-8)
- CC is the cct number (01-12).
The system prompts for a starting extension number.
• Other parameters assigned to ONS and OPS devices:
- COS = 2
- COR = 1
- Tenant = 1
• Other parameters assigned to DNIC and IP sets:
- COS = 1
- COR = 4 for all set types except SUPERSET 430 and
SUPERSET 4150
- COR = 5 for the SUPERSET 430 and SUPERSET 4150
- Tenant = 1
Note: Before an extension number can be automatically assigned, a DNIC
set or DMP must be physically connected to the circuit. If no set or console
is detected on a circuit, that circuit is skipped and no extension number is
assigned.