Operating the PTZ camera
If a PTZ camera is connected to the RS422/485 terminal, Pan/Tilt, Zoom/Focus operations are available from this unit.
Connect the RS422/485 terminal and the camera using a
twisted pair cable.
1
Press the MENU button (the MAIN MENU is
displayed) and select SYSTEM using the control
button (}~).
• A password is requested when pressing the MENU
button. (P7)
2
Place the cursor on PTZ CONTROL and press the
ENTER button.
The PTZ CONTROL screen is displayed.
3
Place the cursor on the settings item and setting.
DATA SPEED: Selecting the communication speed
CHANNEL: Selecting a connected channel
PROTOCOL: Selecting the type of protocol
ADDRESS: Selecting the camera ID (0-63)
4
Press the EXIT/STOP button once the settings are
complete.
1
Select the number of the dome camera connected
using the camera selection button.
2
Press the PTZ button.
The control screen is displayed.
3
Controlling the camera
b Pan/Tilt operations
1 Select "PAN/TILT" using the control button ({|)
and press the ENTER button.
2 Adjust the tilt position using the control button ({|)
and adjust the pan position using the control button
(}~).
• The following message is displayed on the screen
during operations.
Up/Down key: Tilt Up/Down
Left/Right key: Pan Left/Right
b Zoom/Focus operations
1 Select "ZOOM/FOCUS" using the control button
({|) and press the ENTER button.
2 Adjust the zoom using the control button ({|) and
adjust the focus position using the control button
(}~).
• The following message is displayed on the screen
during operations.
Up/Down key: Zoom In/Out
Left/Right key: Focus Near/Far
b Initializing the camera position
Select "INITIALIZE" using the control button ({|) and
press the ENTER button.
• Once the initialization is complete, the following
message is displayed on the screen and the
adjustment position is reset to its default values.
"INITIALIZE SUCCESS!"
4
Press the EXIT/STOP button once operation are
complete.
1
Connection
RS422 RS485
1
TX+ (+Transmit Data)
A
2
TX- (-Transmit Data)
B
3
RX+ (+Receive Data)
–
4
RX- (-Receive Data)
–
2
Settings
When several cameras are connected, select the same
protocol for all cameras.
1234
TX+ TX- RX+ RX-
RS-422/485
SYSTEM
DVR ID DVR
DESCRIPTION
LOAD DEFAULT
ADMIN PASSWORD
NETWORK PASSWORD
DATE FORMAT YYYY/MM/DD
CKLOCK SET
PTZ CONTROL
LANGUAGE ENGLISH
REMOTE CONTROLLER ID 0
D.S.T./SUMMER TIME OFF
MAIN MENU
RECORDLIVE SYSTEM
HDD SETNETWORK SERVICE
DATA SPEED 19200 14400 9600 4800 2400
CHANNEL 1 2 3 4
PROTOCOL - - - -
ADDRESS 0
PTZ CONTROL
3
Operation
• If a PTZ camera is not connected to this unit, the
following message is displayed on the screen.
"Please set up a camera type in setup menu."
• The terminator settings of this unit are set to "ON".
Consult the dealership where this unit was purchased
for any changes.