American Dynamics ADV096HD VCR User Manual


 
11Advanced FunctionsReference page
Alarm Recording
If an alarm occurs, the VCR switches to alarm recording.
page 26 for alarm recording connection
Example)
When ALARM REC MODE is set to L30H and
ALARM REC DURATION is 10 min.
Alarm signal input
L30H
Recording
10 min
Recording Alarm Recording
<MAIN MENU>
DISPLAY
TIMER PROGRAM
RECORDING SET UP
REAR TERMINAL
MAINTENANCE
CLOCK/FIRST TIME SET UP
<RECORDING SET UP>
ALARM REC MODE 6H
ALARM REC DURATION 1M
EMERGENCY REC OFF
SUPER RESOLUTION ON
ONE SHOT•FIELD 1
<RECORDING SET UP>
ALARM REC MODE 6H
ALARM REC DURATION 1M
EMERGENCY REC OFF
SUPER RESOLUTION ON
ONE SHOT•FIELD 1
<RECORDING SET UP>
ALARM REC MODE L30H
ALARM REC DURATION 1M
EMERGENCY REC OFF
SUPER RESOLUTION ON
ONE SHOT•FIELD 1
<RECORDING SET UP>
ALARM REC MODE L30H
ALARM REC DURATION 1M
EMERGENCY REC OFF
SUPER RESOLUTION ON
ONE SHOT•FIELD 1
<RECORDING SET UP>
ALARM REC MODE L30H
ALARM REC DURATION 10M
EMERGENCY REC OFF
SUPER RESOLUTION ON
ONE SHOT•FIELD 1
Special day of the week
Set the recording period by specifying the start and end day of
the week for timer recording.
1. Display <TIMER PROGRAM> menu.
2. Turn JOG to select SPECIAL DW and
turn SHUTTLE to the right.
3. Turn JOG to set the start and end day
of the week, and turn SHUTTLE to the
right.
4. Press MENU button.
The day and present time display appears on screen.
Note
Start day of the week and end day of the week cannot be
identical.
When the recording period of 2 or more programs are
overlapped
The VCR always gives priority to the higher-numbered program.
Info.
To make sure that the HOLIDAY SET UP setting is applied
correctly, set a timer program with HLD in DW column to the
higher-numbered program.
<TIMER PROGRAM>
PROGRAM TO RECORD
HOLIDAY SET UP
SPECIAL DW MON-SAT
Holiday set up
Up to 20 days per year can be set for Holiday for when the timer
recording will be performed, or if HR in PROGRAM TO
RECORD menu is set to SKIP, the timer recording will not be
performed during the programmed period.
1. Display <TIMER PROGRAM> menu.
2. Turn JOG to select HOLIDAY SET UP
and turn SHUTTLE to the right.
<HOLIDAY SET UP> menu
appears.
3. Turn JOG to move the cursor (
) and
turn SHUTTLE to the right.
Each time JOG is turned to the right, the cursor moves
towards right-forward direction.
4. Turn JOG to select the month you want, and turn SHUTTLE
to the right.
5. Turn JOG to select the day you want, and turn SHUTTLE to
the right.
Repeat steps 3 to 5 to set 2 or more days at once.
6. Press MENU button.
The day and present time display appears on screen.
Info.
To erase the pre-set month and day, turn SHUTTLE to the
left while the month item is flashing.
<HOLIDAY SET UP>
01/01 01/15 02/11 03/22
04/29 05/03 05/04 05/05
07/20 09/15 09/23 10/10
11/03 11/23 12/23 - - / - -
- - / - - - - / - - - - / - - - - / - -
MONTH / DAY
1. Press MENU button.
<MAIN MENU> appears.
2. Turn JOG to select RECORDING
SET UP and turn SHUTTLE to the
right.
<RECORDING SET UP> menu
appears.
3. When the cursor (
) is next to
ALARM REC MODE, turn SHUTTLE
to the right.
4. Turn JOG to set the alarm recording
mode you want and turn SHUTTLE to
the right.
5. Turn JOG to select ALARM REC
DURATION and turn SHUTTLE to the
right.
6. Turn JOG to set the alarm recording
duration you want and turn SHUTTLE
to the right.
When set to MAN 1, alarm
recording continues until RST IN
terminal is grounded.
When set to MAN 2, alarm
recording continues while ALM IN
terminal is grounded.
7. Press MENU button.
The day and present time display
appears on screen.
Info.
The index signal is automatically recorded when an alarm
recording begins. (The Index indicator (
) flashes on
the fluorescent display).
Even if an alarm recording is proceeding, the new alarm
recording starts when the next alarm signal is input. (While
an index signal is being recorded and then the next alarm
signal is input, the second signal may not be detected during
skip or index search.)
An alarm recording continues till its end during timer
recording, even if the timer recording end-time reaches.
An alarm recording will be cancelled if the tape reaches its
end.
If the interval between two alarm recording start-times is too
short, the skip or index search may not function correctly.
(
for the minimum interval between two alarm recording
start-times, go to page 18)
Info.
To erase a program:
Select the program number you wish to erase, turn
SHUTTLE to the right (DW column flashes) and then turn
SHUTTLE to the left.