EverFocus ECOR 264-8/4 D2 DVR User Manual


 
51
HD Temperature:
Figure 4-12 Alarm & Event Menu Event - HD Temperature
Log: Check box to record HDD temperature events in the log.
Buzzer: Check box to enable buzzer when hard drive’s temperature is over the “Temp. Warning Limit.
Email Notify: Check box to enable email notification when HDD temperature is over the “Temp. Warning
Limit. Email operation requires that valid email settings have been entered in the Network Setting/Email
setup screen.
Network Alarm: Check box to send out a network alarm to client PC. (requires PowerCon software and
setting up Alarm Server in Network Setup menu)
Stop Recording: Check box to stop recording when HD’s temperature is over the “Temp. Warning Limit.
Temp. Warning Limit: Sets the trigger temperature for HD Temperature event actions. Choose between
50C /122F or 70C /158F.
Alarm Output: This will transmit a signal through the alarm output. It can be set to either NONE (not
active) or 1 (active).
Output Type: Output action will be Transparent and cannot be changed (alarm output remains as long as
the alarm condition is active).