Extron electronic DDS 402 Home Theater Screen User Manual


 
Operation, cont’d
Digital Display Scaler • Operation3-8
Memory Presets menu
Figure 3-7 is a flowchart that shows an overview of the Memory Presets menu, the
Save Presets and Erase Presets submenus, and the available settings.
NEXT
MENU
MENU
NEXT
NEXT
Use either Adjust knob to adjust
the settings of the submenus
Output
Configuration
Advanced
Configuration
Save Preset
NA
<
1
>
2 3
Erase Preset
<
NA
>
1 2 3
Memory
Presets
Figure 3-7 — Memory Presets menu flowchart
Save Presets submenu
Rotate either the Adjust
or the Adjust knob while in the Save Presets submenu
to select (< >) one of three memory presets for the selected input or no preset. Press
the Next button to save the current settings to the selected preset. Select N/A and
press the Next button to exit without saving the settings.
Presets, saved values of the current centering and sizing settings, are saved in non-
volatile memory; when the DDS 402 is powered down and later powered back up,
the settings are available for selection. Saving the settings to a preset overwrites the
settings previously written to that preset.
The centering and sizing adjustments are tailored for the selected output rate.
If you change the output rate and then recall a preset for the earlier rate, the
adjustments recalled in the preset have no effect on the video output. However,
if you then change back to the earlier output rate, the affects of the adjustments
appear on the screen.
Memory presets are recalled using the Input buttons menu. See Input buttons in this
chapter for instructions on recalling a preset.
Erase Presets submenu
Rotate either the Adjust
or the Adjust knob while in the Erase Presets submenu
to select (< >) one of three memory presets to erase. Press the Next button to erase
the preset.