Honeywell
5
Record and
playback
Recording
Mode
Manual recording, motion detection recording, schedule recording and
alarm recording
Priority: Manual recording> alarm recording>motion detection
recording>schedule recording
Recording
Length
1 to 120 minutes single record duration (Default 60 minutes)
Cyclic mode When hard disk is full, system can overwrite previous video file.
Record Search Various search engines such as time, type and channel.
Playback Mode
Various fast play, slow play speeds, manual frame by frame playback
and reverse play mode.
Var
ious File
Switch Ways
Can switch to previous or next file or any file in current play list.
Can switch to file on other channel of the same time (if existing).
Supports continuous file playback; when a file is ended, system
automatically plays the next file in the current channel
Multi-channel
Playback
Support maximum 4-
channel simultaneous
playback.
Support maximum
8-channel
simultaneous
playback.
Support maximum 16-
channel simultaneous
playback.
Display Modes Switch between adaptive window/full screen during playback
Zoom
When in one-window full-screen playback mode, you can select any
zone to zoom in.
Backup
function
Backup Mode
HDD backup
Support peripheral USB backup device. (Flash disk, portable HDD
and etc.)
Supports USB burner (extension function).
Supports network download and backup
Network
Function
Network control
Remote live view of all channels.
DVR configuration through web browser client
Upgrade or maintenance via web browser client
View alarm information such as external alarm, motion detection and
video loss
Supports network PTZ control
File download backup and playback
Duplex transparent COM
Intercom
Motion
Detection and
Alarm
Motion
Detection
Zone setup: 396 (PAL, 22×18) or 330 (NTSC, 22×15) detection
zones.
Various sensitivity levels
Can activate recording, external alarm or screen message prompt in
specified period.
Video Loss
Alarm can activate external alarm or screen message prompt.
External Alarm
Can activate recording, external alarm or screen message prompt in
specified period.
Manual Alarm
Control
Enables or disables alarm input channel.
Supports manual alarm output.
Alarm Input
4-ch alarm input
(
Normal open or
normal close
)
8-ch alarm input
(
Normal open or
normal close
)
16-ch alarm input
(
Normal open or
normal close
)