Icom HF/VHF/UHF ALL MODE TRANSCEIVER TV Receiver User Manual


 
44
5
MEMORY AND SCAN OPERATION
Select VFO mode, then set a frequency.
Close the squelch with [SQL].
Set the desired memory channel as the watching
channel.
Select S2, then push [(F-2)PRI] to start the watch.
•Decimal point blinks while scanning.
When the scan detects a signal, the scan pauses
for 10 sec. or until the signal disappears, depend-
ing on the resume setting.
To cancel the scan push [(F-2)PRI].
Note: The paused condition when detecting a signal
differs depending on the scan resume condition.
resume on: pauses for 10 sec.
resume off: pauses until the signal disappears.
Select memory mode.
Close the squelch with [SQL].
Select S2, then push [(F-1)SCN] to start the mem-
ory scan.
•Decimal point blinks while scanning.
Push [(F-2)SEL] to change the memory scan to
select memory scan.
•Push [(F-2)SEL] for 2 sec. to clear all select memory
channels.
When the scan detects a signal, the scan stops or
pauses depending on the resume setting.
To cancel the scan push [(F-1)SCN].
Note: Two or more memory channels must be desig-
nated as select memory channels for select memory
scan to start.
S2 SCN
SEL V/M
Select
memory mode
Designate
“S.”
F-1
F-2
Push [(F-1)SCN], then [(F-2)SEL].
CH
S
MEMO
PO
S1
5
53792040
10
60dB
USB
Select memory mode.
Close the squelch with [SQL].
Select S2, then push [(F-1)SCN] to start the scan.
•Decimal point blinks while scanning.
When the scan detects a signal, the scan stops or
pauses depending on the resume setting.
To cancel the scan push [(F-1)SCN].
Note: Two or more memory channels must be pro-
grammed for memory scan to start.
S2 SCN
SEL V/M
Select
memory mode
F-1
then push [(F-1)SCN]
CH
MEMO
PO
S1
5
53792040
10
60dB
USB
Select VFO mode.
Select the desired operating mode.
•The operating mode can also be changed while scan-
ning.
Set [SQL] open or closed.
•See page a left for squelch condition.
Select S2, then push [(F-1)SCN] to start the scan.
•Decimal point blinks while scanning.
When the scan detects a signal, the scan turns
OFF, pauses or ignores it depending on the
resume setting and the squelch condition.
•During scan [TS] can be used only when resume is ON.
To cancel the scan push [(F-1)SCN].
Note: If the same frequencies are programmed into
the scan edge memory channels 1A and 1B, pro-
grammed scan does not start.
Programmed scan operation
Memory scan operation
Select memory scan operation
S2 SCN
PRI V/M
Select
VFO mode
Select watching
channel
F-2
Push [(F-2)PRI].
CH
PO
S1
5
53792040
10
60dB
USB
VFO A
Priority watch
CH
VFO A
PO
S1
5
53792040
10
60dB
USB
S2 SCN PRI V/M
Select
VFO mode
F-1
then push [(F-1)SCN]