Icom HF/VHF/UHF ALL MODE TRANSCEIVER TV Receiver User Manual


 
60
10
OPTIONAL INSTALLATIONS/SETTINGS
CR-282
HIGH
-
STABILITY CRYSTAL UNIT
By installing the CR-282, the total frequency stability
of the transceiver will be improved.
Remove the bottom cover as shown on the oppo-
site page.
Remove the 5 screws and 2 flat cables holding the
PLL unit in place.
Remove the existing crystal unit.
Put the CR-282 in the space available as shown in
the diagram.
Adjust the reference frequency at L601 (also R602
and L623 if necessary) using a frequency counter
(60.00000 MHz).
Return the shield case and bottom cover to their
original positions.
CR-282 frequency stability: ±0.5 ppm
(–30°C to +60°C;
–22°F to +140°F)
IF filters
Several IF filters are available for the IC-706MKIIG.
Choose a filter most appropriate to your operating
needs.
Note: After filter installation, specify the installed filter
using initial set mode (items 9, 10). Otherwise, the
installed filter will not function properly.
FL-100
CW NARROW FILTER
500 Hz/–6 dB
FL-101
CW NARROW FILTER
250 Hz/–6 dB
FL-103
SSB WIDE FILTER
2.8 kHz/–6 dB
FL-223
SSB NARROW FILTER
1.9 kHz/–6 dB
FL-232
CW
/
RTTY NARROW FILTER
350 Hz/–6 dB
Remove the top cover as shown on the previous
page.
Install the desired filter as shown in the diagram
below.
•These filters can be installed in either direction.
Replace the top cover.
Filter
CR-282
ribbon
cable
ribbon
cable
L601
R602
L623
Reference freq.
c
(60.00000 MHz)
existing
crystal
PLL unit (bottom)