12
Name Part No. Quantity Per Unit
Blade Set K-7763 1
Front Grip Pad LA2408 2
Rear Grip Pad LA2414 6
STP Service continued
3 — GRIP BACK SENSOR
(senses if the pull cylinder is back)
4 — TRIGGER SENSOR
(senses if the trigger is being pressed)
5 — WIRE OUT SENSOR
(senses if the wire is out of the insertion hole)
6 — SENSOR TEST OFF
(turns all sensor tests off)
If a sensor test is enabled a tone sounds when the test conditions are present. When a sensor test is enabled all other sensor tests are disabled.
To return back to the test mode, press CLEAR. The sensor test will remain enabled when returning back to the test mode, but will be disabled
once the test mode is exited.
0 — TEST THE SENSORS
A list of options, 0 to 11, will appear on the display by using the [ ] and [ ] keys.
1 — AIR BLAST
(toggles the air blast on and off)
2 — PULL CYLINDER
(toggles the pull cylinder forward and back)
3 — CHUTE
(toggles the chute opened and closed)
4 — TRIGGER
(toggles the trigger up and down)
5 — REAR GRIP
(toggles the pull clamp opened and closed)
6 — FRONT GRIP
(toggles the front clamp opened and closed)
7 — WIRE GATE
(toggles the entry hole open and closed)
8 — BLADE ROTATION
This routine is used rotate the thermal blades around. This can be done in three ways.
1 — FULL (rotates the thermal blades a full cycle)
2 — HALF (rotates the thermal blades a half cycle around the wire and when the decimal point is pressed it will finish the cycle)
3 — STEP
[ ] — CCW (by pressing the [ ] key the thermal blades rotate around in the counter clockwise direction)
[ ] — CW (by pressing the [ ] key the thermal blades rotate around in the clockwise direction)
CLEAR — (the thermal blades are rotated back to home, one level back)
CLEAR — (pressing the CLEAR key a second time brings the thermal blades into a full home position and the program back to the test mode)
9 — STRIP POSITION
[ ] — BK (moves the set plate toward the back of the machine)
[ ] — FWD (moves the set plate toward the front of the machine)
CLEAR — (brings the program back to the test mode)
10 — BEEPER
(turns the beeper on and off. This will not work with a sensor test on)
11 — BLADE HEAT
(toggles the blade heat to the current heat setting)
Recommended Replacement Parts
The quantities listed are spare parts needed per unit. The quantities needed depend upon machine usage.
↑
↑
↑
↑
↑
↑
↑
↑