IDEAL INDUSTRIES 45-935 Cable Box User Manual


 
6
STP Operation continued
Heat Adjustment
Heat can be adjusted by pressing [0] through [9] producing corresponding heat values of 0% through 90%. Pressing HIGH sets the heat at 100%. If
the heat is set at 0%, the machine completes the cycle without using the blades. The heat can also be adjusted by pressing HEAT and using the [ ]
and [ ] keys. The heat is adjusted from 0% to 100% in increments of 10%. Pressing the ENTER key exits from the heat entry mode and returns to the
ready mode.
If CLEAR is pressed during a HEAT entry, it returns to the beginning of the HEAT entry mode. If CLEAR is pressed at the beginning of the HEAT entry
mode, it exits the HEAT entry mode and the previous settings are returned.
Thermal Head Rotation Speed Adjustment
Speed can be adjusted by pressing [1] through [9] corresponding to speeds 1 through 9, and pressing HIGH for speed 10.The speed at which the
thermal blades rotate around the wire being stripped can also be adjusted by pressing SPEED and using the [ ] and [ ] keys. The speed is set from 1
to 10, the fastest setting being 10. Pressing the ENTER key exits from the speed adjustment mode and returns to the run mode.
If CLEAR is pressed during a SPEED entry, it returns to the beginning of the SPEED entry mode. If CLEAR is pressed at the beginning of the SPEED
entry mode, it exits the SPEED entry mode and the previous settings are returned.
Pull Grip Pressure Adjustment
Pressure can be adjusted by pressing the numbers corresponding to pressures 05% through 95%, pressing HIGH sets the pressure at 100%.
EXAMPLE:
press [4] then [5] to get pressure at 45%.
The pressure can also be adjusted by pressing PRESSURE and using the [ ] and [ ] keys. Pressure can be
adjusted from 5 to 100 PSI in increments of 5 PSI. Pressing the ENTER key exits from the pressure entry mode and returns to the ready mode.
If CLEAR is pressed during a PRESSURE entry, the display returns to the beginning of the PRESSURE entry mode. If CLEAR is pressed at the
beginning of the PRESSURE entry mode, the display exits the PRESSURE entry mode and the previous settings are returned.
Press
HEAT Field will Flash
or
Press
Press Press
HEAT
20%
ENTER VALUE
10 40 3.10
Press To
Enter Single
Digit Value
BA TC H
ENTER
PRGM.
HIGH
Or Press for
100% Heat
HEAT Field will Flash
20%
ENTER VALUE
10 40 3.10
ENTER
HEAT
20%
ENTER VA LUE
40 3.1010
SPEED
Press
SPEED Field will Flash
or
20%
ENTER VA LUE
40 3.1010
Press
Press
ENTER
Press To
Enter Single
Digit Value
BA TC H
ENTER
PRGM.
HIGH
Or Press for
Speed 10
SPEED Field will Flash
Press
SPEED
Example 1 Example 2
Example 1 Example 2
20%
ENTER VALUE
3.1010 45
PRESSURE
Press
PRESSURE Field will Flash
or
20%
ENTER VALUE
3.1010 40
Press
Press
ENTER
Press
PRESSURE
Press To
Enter Single
Digit Value
BA TC H
ENTER
PRGM.
HIGH
Or Press for
100%
Pressure
PRESSURE Field will Flash
Example 1 Example 2