Intel 05-2450-001 Home Theater Server User Manual


 
22 HMP Release 1.5 for Linux Software Installation Guide — August 2005
Troubleshooting
4.2 Understanding the Install Error Messages
This section describes the error messages that can appear during installation. For convenience, the
error messages have been grouped as follows:
Installation Prerequisites (OS, Kernel, Disk Space)
Packages/RPMs
Config.sh
lsb-intel-hmp-hmp Intel NetStructure Host Media Processing Software
lsb-intel-hmp-docs Intel Documentation Package
lsb-intel-hmp-ooc Orbacus* CORBA Support Package
Note: This is a CORBA support package that is required and runs in the
background.
lsb-intel-hmp-sdk Intel NetStructure Software Development Kit
lsb-intel-hmp-snmp SNMP Component Manager
Table 4. File Locations under /usr/dialogic
Directory Contents
bin All Intel Dialogic executables
cfg Configuration related files that can be viewed and modified by users. (Some configuration
files are also in the data directory.)
data Contains .pcd, .fcd, and .config files.
demos Demonstration programs (in separate subdirectories according to the feature)
docs Documentation
drivers Drivers
inc Header files (symbolically linked into /usr/include) - exists only when SDK is installed
init.d System startup scripts
lib Library files (symbolically linked into /usr/lib)
log Log files that should be checked by users
ooc CORBA support package
qscript QScript tools. These tools are described in the Diagnostic Guide.
sctools Files for SCbus routing convenience functions
Table 3. Software Package Descriptions (Continued)
Package Name Package Description