Klark Teknik DN9344E Universal Remote User Manual


 
HELIX DN9340E/DN9344E Remote Control Software
User Guide
53 of 65
8.2 Global Memory Management
Memories can be simultaneously recalled or stored to/from multiple units from the global Memory
Management screen.
To open the global Memory Management screen
Switch to the FastNav
®
screen and choose Memory Management.
The screen shown below is opened. It has two tabs (of similar appearance) as follows:
Read \ Write Memories - for globally downloading or uploading all user and preset memories between
AddIns and their respective slave units.
Store \ Recall Memory - for uploading or downloading a specific User Memory between AddIns
and their respective slave units.
To Read/Write All Memories from/to multiple units
1 Switch to the Read \ Write Memories tab.
2 Tick the check box of each Unit for which memories should be downloaded/uploaded.
If uploading/downloading to most units, use Select All to tick all units in the destination
list, then clear check boxes as required. When starting a new selection, use Deselect All to
quickly clear all previous ticks.
3 Set the Synchronisation to Get All Initial values from the Audio System or Set All Initial
values from Computer, as required.
4 Ensure the Preset Memories are unlocked at the relevant Units.
5 Click Read All Memories or Write All Memories as required.
Hint
The synchronise direction is specified
here for global uploads and downloads
The status bars show
progress through
the list (above) and
at the current unit
(below).
All or a subset of
Units can be
selected for
updating